Add generic "Create marker here" context menu entry
[pulseview.git] / manual / cli.txt
1 == Command-line Interface
2
3 Even though PulseView has a graphical user interface, there is also a command-line interface that
4 you can make use of. It is meant to provide functions for convenience and debug purposes, not to
5 replace the user interface itself.
6
7 Running 
8
9         pulseview -h
10
11 gives you a list of these functions.
12
13 Since PulseView can't automatically scan for devices connected to a COM port (ttySx on Linux) or
14 Ethernet, you can tell it to look for a specific device using the -d or --driver parameter. Its
15 usage is the same as for sigrok-cli. For example:
16
17         pulseview -d lecroy-xstream:conn=vxi/192.168.178.20/111
18
19 Also, just as with sigrok-cli, you can specify -i / --input-file and -I / --input-format to open
20 a file on startup. Without -I, it is assumed that the file is in the native sigrok format (.sr).
21 You can also specify more than one file but they are all expected to be in the same format then.
22 Example:
23
24         pulseview -i data.csv -I csv:samplerate=3000000
25
26 The remaining parameters are mostly for debug purposes:
27
28         -V / --version          Shows the release version
29         -l / --loglevel         Sets the libsigrok/libsigrokdecode log level (max is 5)
30         -D / --dont-scan        Don't auto-scan for devices
31         -c / --clean            Don't restore previous sessions on startup
32
33 Of these, -D / --dont-scan can be useful when PulseView gets stuck during the startup device scan.
34 No such scan will be performed then, allowing the program to start up but you'll have to scan for
35 your acquisition device(s) manually before you can use them.
36
37 Another potentially useful option is -c / --clean, which can be used when PulseView doesn't start
38 up and you don't know what could cause this.
39
40 Thus, the combination of both parameters can be seen as some kind of "safe mode" for PulseView: